Fixture Units to Pipe Size Reference Values

Lookup practical drainage pipe size by fixture-unit load for horizontal branches and building drains.

Author

Prof. Priya Venkatesh

Plumbing editorial contributor

Indian theoretical physicist from IIT Bombay with postdoctoral work at CERN, researching dark matter candidates

Reviewed for accuracy by

Prof. Zara Khan

Plumbing content reviewer

Pakistani-British education researcher at Cambridge, evaluating digital literacy programs in South Asian rural schools

Last updatedFebruary 22, 2026

PublishedFebruary 22, 2026

On this page

  1. All value pages
  2. Reference table
  3. FAQs
  4. Methodology and review
  5. Related conversions

Reference Value Index

This page lists 12 reference values for quick browsing and lookup.

Back to converter page · View HTML sitemap

All Reference Values

Reference Table

Fixture Units to Pipe Size reference values
SystemMax DFUPipe SizeMin Slope (in/ft)
Horizontal Branch31-1/2 in0.25
Horizontal Branch82 in0.25
Horizontal Branch243 in0.125
Horizontal Branch504 in0.125
Horizontal Branch1806 in0.125
Horizontal Branch3908 in0.125
Building Drain21-1/2 in0.25
Building Drain62 in0.25
Building Drain203 in0.125
Building Drain1604 in0.125
Building Drain3606 in0.125
Building Drain7008 in0.125

Frequently Asked Questions

Frequently asked questions for Fixture Units to Pipe Size and its reference values.

What are drainage fixture units (DFU)?

DFU is a plumbing design unit that represents probable drainage load from fixtures and helps size drainage piping.

Why are branch and building drain tables different?

Different parts of the drainage system can have different loading and sizing rules, so lookup limits vary by system type.

Does this replace full plumbing code tables?

No. Use this as a quick planning reference; final design must follow adopted local plumbing code and authority requirements.

Why include minimum slope with pipe size?

Adequate slope is essential for gravity drainage performance and is typically tied to pipe size and code requirements.

Methodology and Review

Each row on this page links to a value detail page derived from the same conversion data file as the main calculator and reference table. This reduces inconsistencies across page variants.

Editorial metadata and structured data are rendered across the converter page and linked value pages. Review policies are documented in our review process and editorial policy.